  • Suggested Queries

Which PAT Tester
is right for you
?

Would you like your tester to be able to store test results for easy download to a PC?

Will you be testing portable RCDs, or surge protected equipment, and/or will you need to do powered leakage test?

Do you require measurement test result values?

Will you require a powered 110V leakage test and/or a flash test?

Would you like to store images against test results (e.g. visual inspection & failed appliances) for full traceability, complete other health and safety tests and inspection records, and/or use a USB flash drive to transfer data to and from the tester?

Would you like to upload assets for faster retesting, and/or have the flexibility to customise user and test settings?

Would you like to include asset details against test records (e.g. description, location, site etc.)?

Seaward

Ideal for:

  • Low-mid volume testing which is likely to include portable RCDs, surge protected equipment or where powered leakage test are required
  • Manually recording measurements or downloading basic test results to PC

Electrical Test Functions:

  • Earth continuity (200mA)
  • Insulation resistance at 250/500V
  • IEC lead test
  • Protective conductor current
  • Touch current
  • 3 Phase leakage current (requires adaptor)
  • Alternative leakage current
  • RCD trip time
  • Power socket test

General Features:

  • Handheld
  • Compatible with Test n Tag Pro printer
  • Single key save and single key download
  • Memory for 999 records

Seaward

Ideal for:

  • Low volume testing
  • Manually recording measurements or basic data logging and label printing via PATMobile app

Electrical Test Functions:

  • Mains supply check
  • IEC lead test
  • Earth continuity (200mA)
  • Insulation resistance (500V)
  • Alternative substitute leakage

General Features:

  • Handheld
  • Battery powered
  • Simple data logging via PATMobile app
  • Compatible with Test n Tag Pro printer using PATMobile app*
*Android only
Seaward

Ideal for:

  • Basic, low volume testing
  • Manually recording measurements or basic data logging and label printing via PATMobile app

Electrical Test Functions:

  • Mains supply check
  • IEC lead test
  • Earth continuity (200mA)
  • Insulation resistance (500V)

General Features:

  • Handheld
  • Basic pass/fail data logging via PATMobile mobile app
  • Compatible with Test n Tag Pro printer using PATMobile app*
*Android only
Seaward

Ideal for:

  • High volume PAT testing including equipment that requires a flash test (e.g. hire equipment)
  • Testing 110V tools and appliances
  • Testing on a 110V or 230V supply

Electrical Test Functions:

  • All tests required by the IET 4th Edition Code of Practice

General Features:

  • QWERTY keypad
  • Memory for 6,000 records
  • PC download/upload
  • Mains powered

Seaward

Ideal for:

  • Mid volume testing to meet all testing requirements of the IET Code of Practice, including fixed appliances
  • Downloading detailed test results to a PC

Electrical Test Functions:

  • All tests required by the IET 4th Edition Code of Practice

General Features:

  • Colour screen
  • QWERTY keypad
  • Memory for 2,000 records
  • PC download
  • Printer compatible
  • Point to point measurement (Rpe & IR) needs optional accessory
  • 25 user configurable electrical test/visual inspection sequences

Seaward

Ideal for:

  • Mid-high volume testing to meet all testing requirements of the IET Code of Practice, including fixed appliances
  • Downloading detailed test results to a PC

Electrical Test Functions:

  • All tests required by the IET 4th Edition Code of Practice

General Features:

  • Colour screen
  • QWERTY keypad
  • Memory for 10,000 records
  • PC download/upload
  • Retest calculator
  • Ability to use (2D) QR codes
  • Built in electrical risk assessment tools with suggested retest period calculator
  • User configurable tests for non-electrical tests and inspections

Seaward

Ideal for:

  • Mid-high volume testing to meet all testing requirements of the IET Code of Practice, including fixed appliances
  • Downloading detailed test results to a PC
  • Uploading appliance details to the tester for faster retests
  • Recording any workplace test or inspection and completing health & safety

Electrical Test Functions:

  • All tests required by the IET 4th Edition Code of Practice

General Features:

  • Colour screen
  • QWERTY keypad
  • Memory for 50,000 records & 2,000 images
  • PC download/upload
  • Universal risk assessment
  • Ability to use (2D) QR codes
  • On-board colour camera with flash
  • Built in universal and electrical risk assessment tools

Which PAT Tester is right for you?

PrimeTest 50
PrimeTest 100
PrimeTest 250+
Apollo 400+
Apollo 500+
Apollo 600+
Supernova Elite

About Seaward

With over 30 years experience in the field, Seaward leads the way in product solutions that enable companies and organisations to comply with electrical safety testing legislation. UK-based but with worldwide distribution, Seaward is renowned for continuous product development and innovation in portable appliance testing (PAT) and associated accessories such as PAT software.

Rapid stock a comprehensive range of Seaward PAT testing devices, from entry level models in the PrimeTest range to the feature-rich Apollo 600, which integrates PAT testing with risk assessment in order to comply with the latest IET Code of Practice. Seaward PAT testing kits provide professionals with all-in-one solutions, including label printers, barcode scanners, power leads, software access and carry cases.

Seaward recognises the needs of test professionals and the practical requirements of PAT testing today. Whether you run a PAT testing business or require equipment for in-house PAT testing, there is only one name to trust: Seaward.

Feature Comparison Chart Apollo
600+
Apollo
500+
Apollo
400+
Supernova Elite PrimeTest 250+ PrimeTest 100 PrimeTest
50
General features
Handheld

Battery/mains powered

Mains only

Battery (mains for PE current test)

Battery

Battery

Colour screen

QWERTY keypad

Internal memory

Up to 50,000 records
+ 2,000 photos

Up to 10,000 records

Up to 2,000 records

Up to 6,000 records

Up to 999 records

Scanner & printer compatible

Printer only

Printer only (PATMobile app*)

Printer only (PATMobile app*)

Password controlled user accounts

Set up multiple user accounts with varying levels of privileges

(Same privileges)

Clone facility to set up multiple testers

Checkbox supplied as standard

Test & inspection features
Auto-increment asset ID

PAT setup option to allow for custom menus

Enter asset description after test using keypad or barcode scanner

Comprehensive electrical safety test features

Point to point measurement (Rpe & IR)

Optional accessory required

User configurable electrical test/visual insepction sequences

100

100

25

20

User set sites & locations

100

100

50

19 sites / 49 locations

Risk-based retest calculator

User definable comments lines against test records

4

4

Configurable checklists for any workplace test or inspection (User tests)

On-board camera

Universal risk assessment

Health & safety certificates

Data transfer
Barcode (1D) scanner connectivity

QR (2D) scanner connectivity

(No QR code)

RFID reader connectivity

Print pass & fail labels with 1D barcode

Print pass & fail labels with QR (2D barcode)

Add your company logo to labels (1D on large labels only)

Select from various label formats to print

6

6

6

Download to PC via USB cable

Data transfer via USB flash drive

Filter results to be downloaded

Upload previous results to tester for retest

Electrical test functions
Accurate earth continuity circuit

N/A

Mains supply check

IEC lead test

Earth test lead null

4-Wire

Earth continuity

200mA

200mA

200mA

100mA/200mA/
4A/10A/25A

200mA

200mA

200mA

Insulation resistance

250V/500V

250V/500V

250V/500V

250V/500V

250V/500V

500V

500V

PE conductor current (earth leakage)

230V only

230V only

230V only

110V/230V

230V only

Touch current

230V only

230V only

230V only

110V/230V

230V only

Alternative substitute leakage

RCD test

Flash test

3 phase leakage

Requires adaptor

Requires adaptor

Requires adaptor

Requires adaptor

230V/110V input/output

Point to point testing

(requires accessory)

*Android Only

Table viewed better on a larger screen.