The Siemens 6ES7241-1AH32-0XB0 is a CM 1241 Communication Board that is used for fast, high-performance serial data exchange via point-to-point connections. Point-to-point connection is possible via the RS232 9-pin D-Sub Male connection to SIMATIC S7 automation systems, or the systems of many other manufacturers including printers, robot controls, modems, scanners and bar code readers, etc.
The communication board is directly plugged into the CPU, enabling the controller to be expanded without taking up any additional space. This allows users to adapt their controller even to more complex tasks. If the task is expanded subsequently, the controller can be upgraded.
- SPS component (category): SPS add-on module
- Number of interfaces: 1
- Power loss typical: 1.1W
- Cable length: 10m
- Rated output voltage: 24V
- Temperature range: -20°C to +60°C
- Weight: 150g
- Connection type: RS232 9-pin D-Sub Male
- Type: CM 1241
- Manufacturer's part: Siemens 6ES7241-1AH32-0XB0
| Appendant operation agent (Ex ia) |
false |
| Appendant operation agent (Ex ib) |
false |
| Certified for UL hazardous location class I |
N/A |
| Certified for UL hazardous location class II |
N/A |
| Certified for UL hazardous location class III |
N/A |
| Certified for UL hazardous location division 1 |
N/A |
| Certified for UL hazardous location division 2 |
N/A |
| Certified for UL hazardous location group A (acetylene) |
N/A |
| Certified for UL hazardous location group B (hydrogen) |
N/A |
| Certified for UL hazardous location group C (ethylene) |
N/A |
| Certified for UL hazardous location group D (propane) |
N/A |
| Certified for UL hazardous location group E (metal dusts) |
N/A |
| Certified for UL hazardous location group F (carbonaceous dusts) |
N/A |
| Certified for UL hazardous location group G (non-conductive dusts) |
N/A |
| Depth |
75mm |
| Display |
No |
| Explosion safety category for dust |
N/A |
| Explosion safety category for gas |
N/A |
| Height |
100mm |
| IO link master |
false |
| Mobile communication standard 2G (GSM) |
false |
| Mobile communication standard 3G (UMTS) |
false |
| Mobile communication standard GPRS |
false |
| Number of HW-interfaces CAN |
N/A |
| Number of HW-interfaces industrial Ethernet |
0 |
| Number of HW-interfaces other |
0 |
| Number of HW-interfaces parallel |
0 |
| Number of HW-interfaces RS-232 |
1 |
| Number of HW-interfaces RS-422 |
0 |
| Number of HW-interfaces RS-485 |
0 |
| Number of HW-interfaces serial TTY |
0 |
| Number of HW-interfaces USB |
0 |
| Number of HW-interfaces wireless |
0 |
| Number of interfaces PROFINET |
0 |
| Operating Voltage |
24V DCV |
| Performance level according to EN ISO 13849-1 |
N/A |
| Power Consumption |
N/A |
| Radio standard Bluetooth |
false |
| Radio standard WLAN 802.11 |
false |
| Redundancy |
false |
| SIL according to IEC 61508 |
N/A |
| Suitable for safety functions |
false |
| Supporting protocol for ASI |
false |
| Supporting protocol for AS-Interface Safety at Work |
false |
| Supporting protocol for CAN |
false |
| Supporting protocol for Data-Highway |
false |
| Supporting protocol for DeviceNet |
false |
| Supporting protocol for DeviceNet Safety |
false |
| Supporting protocol for EtherCAT |
false |
| Supporting protocol for EtherNet/IP |
false |
| Supporting protocol for Foundation Fieldbus |
false |
| Supporting protocol for INTERBUS |
false |
| Supporting protocol for INTERBUS-Safety |
false |
| Supporting protocol for KNX |
false |
| Supporting protocol for LON |
false |
| Supporting protocol for Modbus |
true |
| Supporting protocol for other bus systems |
false |
| Supporting protocol for PROFIBUS |
false |
| Supporting protocol for PROFINET CBA |
false |
| Supporting protocol for PROFINET IO |
false |
| Supporting protocol for PROFIsafe |
false |
| Supporting protocol for SafetyBUS p |
false |
| Supporting protocol for SERCOS |
false |
| Supporting protocol for SUCONET |
false |
| Supporting protocol for TCP/IP |
false |
| Transmission rate |
N/A |
| Type |
Add-on module |
| Type of data transmission |
N/A |
| Width |
30mm |
| With optical interface |
false |
| With potential separation |
true |