| DC Voltage | | | | | |
|
Range | Accuracy | Resolution | Notes | | |
|
400mV | 0.08% ± 4 dig. | 10µV | Max. Input 265V DC/AC rms | | |
|
4V | 0.08% ± 4 dig. | 100µV | Input impedance 10MΩ nominal | | |
|
40V | 0.08% ± 4 dig. | 1mV | Max. input 1kV DC or AC pk | | |
|
400V | 0.08% ± 4 dig. | 10mV | NMR: >60dB @ 50/60Hz | | |
|
1000V | 0.09% ± 4 dig | 100mV | CMR: >90dB @ DC/50Hz/60Hz | | |
|
AC Voltage (True RMS, 4000 count scale length) | | | | | |
|
Range | | Accuracy | | Resolution | |
|
| 45Hz - 400Hz | 400Hz - 5kHz | 5kHz - 20kHz | | |
|
400mV | | 1% ± 4 dig. | 3% ± 4 dig. | 100µV | |
|
4V | | | | 1mV | |
|
40V | 0.5% ± 4 dig. | 2% ± 4 dig. | 5% ± 4 dig. | 10mV | |
|
400V | | 3% ± 4 dig. | | 100mV | |
|
750V | 1% ± 4 dig. | | | 1V | |
|
Accuracies apply for readings between 10% and 100% of full scale. Additional error at crest factor = 3 is typically 1%. Input impedance = 10MΩ nominal. Max. input = 750V rms, 1kV pk. (265V rms on 400mV range). 1kΩ unbalanced CMR = >60dB at DC or 50Hz (60Hz rejection available as factory option.) Resistance | | | | | |
|
Range | Accuracy | Resolution | Notes | | |
|
400Ω | 0.15% ± 6 dig. | 0.1µA | * 400Ω specification applies after null | | |
|
4kΩ | 0.1% ± 4 dig. | 100mΩ | Max. input 265V DC or AC rms on any range. | | |
|
40kΩ | 0.1% ± 4 dig. | 1Ω | Max. open circuit voltage 4V | | |
|
400kΩ | 0.15% ± 4 dig. | 10Ω | | | |
|
4MΩ | 0.3% ± 6 dig. | 100Ω | 40MΩ accuracy applies up to 20MΩ | | |
|
| | | thereafter add 1% | | |
|
40MΩ | 1.0% ± 10 dig. | 1kΩ | | | |
|
DC current | | | | | |
|
Range | Accuracy | Resolution | Notes | | |
|
4mA | 0.1% ± 4 dig. | 0.1µA | Max. input 1A (Fused) | | |
|
400mA | 0.1% ± 4 dig. | 10µA | Voltage burden <500mV | | |
|
10A (up to 1A) | 0.3% ± 4 dig. | 1mA | | | |
|
10A (up to 5A) | 0.1% ± 4 dig. | 1mA | Max. input 10A (Fused) | | |
|
10A (up to 10A) | 3.0% ± 10 dig. | 1mA | Voltage burden <500mV | | |
|
AC current (True RMS, 4000 count scale length) | | | | | |
|
Range | Accuracy | Resolution | Notes | | |
|
1mA | 0.5% ± 4 dig. | 1µA | Max. input 1A (Fused) | | |
|
100mA | 0.5% ± 4 dig. | 100µA | Voltage burden <500mV | | |
|
10A (up to 1A) | 0.8% ± 4 dig. | 10mA | | | |
|
10A (up to 5A) | 1.5% ± 4 dig. | 10mA | Max. input 10A (Fused) | | |
|
10A (up to 10A) | 3.0% ± 4 dig. | 10mA | Voltage burden <500mV | | |
|
Accuracies apply over 45Hz to 10kHz for readings between 10% and 100% of range. Additional error at crest factor = 3 is typically 1%. | | | | | |
|
Frequency | | | | | |
|
Range | Accuracy | Resolution | Notes | | |
|
4kHz | 0.01% ± 1 dig. | 0.1Hz | Sensitivity selected by AC range | | |
|
40kHz | 0.01% ± 1 dig. | 1Hz | setting | | |
|
Sensitivity better than 40mV (400mV range), better than 10% of range (other Vac & lac ranges). | | | | | |
|
All accuracies apply for 1 year, 198C to 258C. Temperature coefficient outside these limits is <0.1 x quoted range accuracy per 8C | | | | | |
|
Further Functions | | | | | |
|
Continuity | | | | | |
|
Selects 4kΩ range and sounds audible tone for impedance <10Ω. Max. input 265V DC or AC rms. | | | | | |
|
Diode Test | | | | | |
|
Displays junction voltages up to 3V at a test current of 1mA at 1V. Max. open circuit voltage approximately 4V. Max.input 265V DC or AC rms | | | | | |
|
Null (Relative): | Stores current reading and subtracts it from future readings | | | | |
|
Hold: | Reading is frozen until released | | | | |
|
T-Hold | Reading is frozen when it becomes stable | | | | |
|
Min/Max: | Minimum and maximum readings are stored | | | | |
|
Display and Range Control | | | | | |
|
0.56in (14mm) LED display. Annunciators for all ranges, functions and smart modes. Scale Length 43/4 digits (±40,000 counts) except ac ranges (4,000 counts). Reading rate 2.5 per second. Overrange shows OFL on display. Each measurement function can use automatic or up/down manual ranging. | | | | | |
|
RS-232 interface | | | | | |
|
Opto-isolated bi-directional RS-232 interface. 9600 baud. | | | | | |
|
General | | | | | |
|
Power: | 230V or 155V AC nominal 50/60Hz, adjustable internally: operating range ±14% of nominal; 3VA max.; Installation category II | | | | |
|
Size: | 260(W) x 88(H) x 235(D)mm, exel. handle/feet | | | | |
|
Weight: | 2.0kg | | | | |
|
Operating range: | +5 to 40°C, 20-80% RH | | | | |
|
Storage range | -40 to +70°C | | | | |
|
Safety: | Complies with EN61010-1 | | | | |
|
EMC: | Complies with EN55081-1 and EN50082-1 | | | | |
|
|