A float switch suitable for vertical mounting and both falling or rising fluid levels.

  • Consists of a sealed SPST reed switch and a float-mounted magnet, which actuates the reed switch depending on the level of liquid in the vessel
  • Typical applications include high or low level sensing in reservoirs, overflow prevention, etc.
  • Supplied with mounting kit permitting either internal or external fitting
  • Terminated in 0.5m flying leads


Product details Hints & Tips

Description

Code

RoHS

Datasheets

1+

Manufacturer Part #: VS801-51

Float Switches - Vertical

61-1315ROHS CompliantTechnical Datasheet£6.28

In stock
despatch same day

Buy

Technical Specification

Only part of this technical specification is being displayed. Click here to expand
Contact configurationSPST
Max. current1A
Max. voltage100V DC/120V AC
Contact rating15W
Body materialUL listed glass-filled polypropylene
Operating temperature–30°C to +110°C (continuous hot water 80°C max.) (non continuous hot water 100°C max.)
Min. liquid S.G.0.65
Overall lengthFloat diameterMftrs. typeOrder code
Vertical8922.2VS801-5161-1315


Questions





Question by Darren Zimmerman | Product code: 61-1315
29th February 2012

QSorry for asking something so basic, but I'm sure it must be relatively straight forward to cobble something together??? I have an RO system that produces water. The water pipes into a 25L jerrican. What I would like to do is set up an automated mechanism to divert the water to a separate t-piece outlet when one jerrican fills so that the water goes into a second container. Hope that makes sense, really appreciate any advice. Realise this isn't exactly what your 'submit a question' section is for, but here's to hoping. Thanks, Darren
AThanks for your enquiry Darren. Something like the 61-1360 or a 61-1300 would be a suitable sensor to detect that the jerry can is full. This could either activate a pump or diversion process that would be activated by the sensor.


Reviews


Be the first to submit a review