Timeguard EASSSZK Emerg Assist Alarm Kit Stainless Steel Single Zone



Order Code: 23-9206
Manufacturer: Timeguard
Manufacturer Part No: EASSSZK
View all from this manufacturer
 

View full technical specification
 


View full product range View full product range

QtyPrice
1+£143.47
ROHS Compliant
ROHS Compliant



normally despatched 5-7 days


Receive stock notification by text or 



 
Key Features

Data Sheets

The Timeguard EASSSZK Emergency Assist Alarm Kit Stainless Steel Single Zone is single zone control panel kit. This is available and used for where assistance may be required in WC areas, changing rooms, bedrooms etc. With a 2 wire connection between control panel, pull cord, reset button and overhead door alert flasher, installation could not be simpler making it a must have for new installations and existing conversions.

The basic system consists of a Control Unit (which is powered by AC mains supply) connected by an extra low voltage 2-wire link to a Pull Cord Unit which is in turn connected to an Over-Door Unit by another extra low voltage 2-wire link. The Over-Door Unit is then connected to a Reset Unit by a further extra low voltage 2-wire link.

When the pull cord, mounted adjacent to the W.C., is pulled, the red L.E.D. on the Pull Cord Unit is activated until the system is reset, assuring the disabled person in distress that the system has been activated. The sounder and the light on the Over-Door Unit outside the cubicle, are activated intermittently.

At the Reset Unit inside the cubicle, the light and sounder are activated intermittently and will both be further reassuring the person in distress. At the Control Unit the alarm light and the sounder are activated continuously. Either the Over-Door Unit or the Control Unit will attract the attention of an appropriate person either directly or indirectly and that person will note the zone in alarm, press the reset button at the Control Unit clearing the alarm and then investigate the toilet cubicle in question.

Note: Reset button at the Control Unit can be disabled by moving the reset selection switch to the OFF position. At any time if the difficulty is resolved the person in distress can clear the alarm by pressing the reset button in the cubicle.


Kit consists of::

  • 1 x EASSCP1 - Single Zone (Stainless Steel Finish) Control Panel - 2 gang
  • 1 x EASSRB18 - Reset Button (Stainless Steel Finish) - single gang
  • 1 x EAPC1 - Pull Cord
  • 1 x EASSDF1 - Over Door Flasher (Stainless Steel Finish)
  • 1 x EADS - Disabled Sticker
  • Manufacturers part no. Timeguard EASSSZK

Technical Datasheet IconTechnical Specification

Technical Specification

Only part of this technical specification is being displayed. Click here to expand
Control Unit Supply voltage: 230V (+10%, -15%) 50Hz
Operating temperature: +5°C to +40°C
Reserve battery: Metal Hydride (rechargeable) PP3, 9V
Alarm Output: DC voltage through 470Ω resistor.
Maximum pull force on pull cord: 200N
Reset button marking: Visually and with Braille
Intensity of sounders: Control Unit and Reset Units 65dB at 30cm
Over-Door Unit 78dB at 30cm
Angular coverage of indicator: 180° on Over-Door Unit:
EC directives: Conforms to 73/23/EEC and 89/336/EEC